EVS Solar Inverters 1KW to 10KW off Grid Hybrid 24V 48V 60V 72V Inverter Pure Sine Wave for Lead Acid Battery 10KVA Capacity
- Battery Type:Lead Acid Battery, Inside or external connect
- Capacity:10kVA
- Place of Origin:Guangdong, China
- Brand Name:EVS
- Model Number:EVS-A1-6000W
- Phase:Single Phase
- Protection:Overvoltage
- Weight:15Kg
- Type:STANDBY, Off-grid Power Inverter
- Application:Security / Monitoring / Alarm
- Electric Energy:6000 Wh
- Function:Telecom base stations
- Model:Rack mount C6KR
- Logo:Can be design according to customer
- Wave Form:Pure Sine Wave Online Ups
- Display:LCD+LED Display
Product Overview:
This series of power supplies has been carefully designed and optimized to meet the high standard requirements of UPS inverters for different fields and electrical equipment. Whether in home, commercial, or industrial environments, stable and reliable sine wave AC power supply can be provided to ensure the safe and efficient operation of electrical equipment. Suitable for inverter or charging or emergency power backup situations with DC voltages of DC12V, DC24V, DC36V, DC48V, DC60V, DC72V.
Field of use:
In vehicle system: Provides stable energy storage power for vehicle electronic devices, suitable for various in vehicle charging and inverter.
Commercial use: Suitable for maintaining power in various electronic devices in commercial environments, such as cash registers, lighting, etc.
Industrial application: Provide reliable uninterrupted power supply for industrial equipment, ensuring the continuity of production power supply.
Civil equipment: Home energy storage backup, commonly used appliances such as air conditioners, televisions, and refrigerators can all be powered by this inverter power supply.
Telecommunications and electricity: providing uninterrupted power supply for key equipment such as telecommunications base stations and power monitoring.
Main uses
Household appliances: air conditioning, television, refrigerator, washing machine, etc.
Office equipment: computers, printers, copiers, etc.
Commercial equipment: cash registers, POS machines, advertising display screens, etc.
Electric tools: various electric tools and mechanical equipment.
Lighting system: indoor and outdoor lighting equipment.
Industrial equipment: production lines, mechanical equipment, etc.
Telecommunications equipment: communication base stations, network equipment, etc.
Core features:
1. High quality power output
Pure sine wave output: ensures that the waveform is superior to the mains power, providing a stable power supply.
No clutter interference: Ensure the safety of load equipment and avoid damage caused by power supply issues.
Fast UPS conversion: The conversion time is less than 8ms, ensuring electrical continuity and stability.
2. Intelligent management and maintenance
Intelligent CPU control: modular design, simplified maintenance process.
Reduce maintenance costs: Improve equipment stability, reduce maintenance frequency and costs.
3. Intuitive user interface
LED and LCD display screens: Real time display of operating parameters, convenient operation.
Fault information display: The fault is directly displayed, making it easy to quickly identify and solve the problem.
4. Efficient energy conversion
High conversion efficiency: up to 92% in half load environment and over 98% in mains environment.
Low loss: In energy-saving mode, the power consumption is as low as 8W, achieving high efficiency and energy conservation.
5. Multi functional charging support
Auxiliary charging: Three stage intelligent charging, compatible with various battery types such as lead-acid, lithium batteries, solid-state batteries, etc.
6. Intelligent temperature control system
Energy saving and durable fan: prolongs equipment life and ensures stable operation.
7. Powerful load capacity
Inverter performance: A 1KW inverter can drive a 1-horsepower air conditioner, and so on, with strong load driving capability.
Usage advantage: able to cope with various load demands and can run for 99% of the load for a long time.
8. Long life circuit design
Power frequency circuit: Made of high-quality electronic materials, it has high stability, long service life, and a normal service life of more than ten years.
9. Comprehensive protection mechanism
Multiple protection functions: including low voltage, high voltage, high temperature, short circuit, overcurrent, overload, etc., to ensure equipment safety.
10. Anti interference design
Super strong anti-interference ability ensures stable operation in complex electromagnetic environments, and outputs pure sine wave alternating current.
11. Flexible configuration options
Optional settings: 50HZ/60HZ optional, AC/DC priority mode adjustable, battery type optional, charging current adjustable, Chinese and English optional, energy-saving options, etc.
12. High quality components
High quality electronic accessories: including power frequency transformers, copper terminal blocks, all copper branded wires, etc., to ensur



| DC input specifications | ||||||||||||||||||||||
| Rated voltage | DC12/24/36/48/60/72V~AC220V | DC12/24/36/48/60/72V~AC110V | ||||||||||||||||||||
| Working voltage range | If DC12V | 10V-16V±0.5V | ||||||||||||||||||||
| If DC24V | 20V-32V±1V | |||||||||||||||||||||
| If DC36V | 30V-47V±1V | |||||||||||||||||||||
| If DC48V | 40V-63V±1V | |||||||||||||||||||||
| If DC60V | 50V-79V±1V | |||||||||||||||||||||
| If DC72V | 60V-94V±1V | |||||||||||||||||||||
| AC input parameters | ||||||||||||||||||||||
| AC Rated voltage | 220VAC system | 110VAC system | ||||||||||||||||||||
| Input voltage waveform | Sine wave (grid or generator) | Sine wave (grid or generator) | ||||||||||||||||||||
| Optional AC voltage | 220Vac/230Vac/240Vac | 110Vac/120Vac/130Vac | ||||||||||||||||||||
| Low voltage turn off | 140Vac±3% | 70Vac±3% | ||||||||||||||||||||
| Low voltage recovery | 147Vac±3% | 74Vac±3% | ||||||||||||||||||||
| High voltage turn off | 260Vac±3% | 131Vac±3% | ||||||||||||||||||||
| High voltage recovery | 250Vac±3% | 126Vac±3% | ||||||||||||||||||||
| Low voltage off charging | ≤147V Stop charging150VRestore | ≤74VStop charging76VRestore | ||||||||||||||||||||
| High voltage off charging | ≥250VStop charging247VRestore | ≥126VStop charging124VRestore | ||||||||||||||||||||
| Frequency | 50HZ(45-55HZ) 60HZ(55-65HZ) When using a generator, the generator frequency cannot exceed this range | |||||||||||||||||||||
| Grid charging method | Three stages: | |||||||||||||||||||||
| Constant current charging (constant current stage) → Constant voltage charging (constant voltage stage) → Float charging (constant voltage stage) | ||||||||||||||||||||||
| Charging overvoltage | Rated DC | 12V | 24V | 36V | 48V | 60V | 72V | |||||||||||||||
| Voltage/V | 15.6 | 31.1 | 46.6 | 62.2 | 77.7 | 93.3 | ||||||||||||||||
| Protection instructions | When other chargers charge the battery, causing the battery voltage to be too high, the inverter will protect it | |||||||||||||||||||||
| Max charging efficienc | ≥85% | |||||||||||||||||||||
| Efficiency of grid supply | ≥98% | |||||||||||||||||||||
| Conversion time | <8ms (AC to DC) OR (DC to AC) | |||||||||||||||||||||